K-SCHALTVENTILE 3/2 MULTIFIX
On-off valves (3/2-way valves)产品图
属性
入口压力 |
Min. 2 bar, max. 10 bar |
介质温度 |
max. 60 °C |
环境温度 |
Max. 60 °C |
电接口 |
Device plug PG 9, type B, EN 175301-803 |
保护等级 |
IP 65 (P 54) acc. to DIN 40050 |
相对接通持续时间 |
100 % |
排气接口 |
Silencer G 1/4 |
密封材料 |
NBR |
壳体 |
Die-cast zinc |
流量值测量 |
At P1 = 6 bar and pressure drop Δp = 1 bar |
描述
Pneumatic systems or parts of systems can be switched on and off by means of anelectrical signal. When they are switched off, the system is relieved at the same time.
提示
其它数据应客户要求提供。
货品
向上排列
向下排列
名称 | 螺纹 | 流量 (L/min) |
电磁线圈 | A (mm) |
B | C (mm) |
D (mm) |
E (mm) |
结构尺寸 |
---|---|---|---|---|---|---|---|---|---|
K- 07 25 11 65 | G 1/4 | 900 | 24 V AC, 50 Hz | 47,8 | 138,7 mm | 43,7 | 26,0 | 17,5 | 1 |
K- 07 25 11 66 | G 1/4 | 900 | 230 V AC, 50 Hz | 47,8 | 138,7 mm | 43,7 | 26,0 | 17,5 | 1 |
K- 07 25 11 67 | G 1/4 | 900 | 110 V AC, 50 Hz | 47,8 | 138,7 mm | 43,7 | 26,0 | 17,5 | 1 |
K- 07 25 11 68 | G 1/4 | 900 | 24 V DC | 47,8 | 138,7 mm | 43,7 | 26,0 | 17,5 | 1 |
K- 07 25 11 69 | G 1/2 | 4000 | 24 V AC, 50 Hz / 12 V DC | 68,8 | 185,0 mm | 56,2 | 33,5 | 44,1 | 2 |
K- 07 25 11 70 | G 1/2 | 4000 | 230 V AC, 50 Hz | 68,8 | 185,0 mm | 56,2 | 33,5 | 44,1 | 2 |
K- 07 25 11 71 | G 1/2 | 4000 | 110 V AC, 50 Hz | 68,8 | 185,0 mm | 56,2 | 33,5 | 44,1 | 2 |
K- 07 25 11 72 | G 1/2 | 4000 | 24 V DC | 68,8 | 185,0 mm | 56,2 | 33,5 | 44,1 | 2 |
订购指南
On-off valves are also available in a pneumatically operated version. Please ask for more information.
附件
- K-SCHALLDAE SINTERBR GE MS1
- Silencers, sintered bronze, with brass hexagon nut and brass thread
备件
- K-KOPPELPAKET MEHR
- Coupling packet
- K-KOPPELPAKET SCHMA
- Coupling packet
- K-GERAETESTECKER
- Coupling socket
- K-HALTERBAUSATZ MULTIFIX
- Holder
- K-MAGNETSPULE MULTIFIX
- Solenoid
- K-WV 3/2 VORSTEU HAND MULTIFIX
- 3/2-way valve
免责声明
尽管经过了仔细审阅,但我们无法完全排除发生错误的可能,对所提供的信息数据本公司不承担任何责任。
本在线目录册的所有信息数据均以现行标准和同行工伤事故保险联合会的规则为依据。只有遵守了本公司的安装规程,才能保证产品的安全性能。若未遵守所有所述的规则,则会影响产品的功能安全性能,从而导致丧失保修资格。本公司的保修服务仅限于HANSA-FLEX产品。本公司的产品处于不断改进中,因此可能发生技术更改。