FI MD GEH
High pressure filter 400barProduct image
Properties
Design |
without bypass valve, without clogging indicator |
Temp. min. |
-10 °C |
Temp. max. |
120 °C |
Material |
Filter head of GGG |
Operating pressure |
up to 315 bar |
Scope of supply |
without filter element |
Description
Pressure filter for pipeline installation
Connector for clogging indicator M20 x 1.5 sealed with bolt
Note
Dimension “L”: clearance required for changing the filter element
Item
Sort upwards
Sort downwards
Identification | for filter type | G1 | L (mm) |
L1 (mm) |
L2 (mm) |
Ø A (mm) |
Ø B (mm) |
BD (bar) |
AF (mm) |
Weight (kg) |
---|---|---|---|---|---|---|---|---|---|---|
FI MD GEH N 040 050 G12 | FI MD 040, 050 | G 1/2” | 80,0 | 189,0 | 31,0 | 92,0 | 66,0 | 315 | 27 | 3,60 |
FI MD GEH N 060 075 G34 | FI MD 060, 080 | G 3/4” | 80,0 | 267,0 | 31,0 | 92,0 | 66,0 | 315 | 27 | 3,90 |
FI MD GEH N 080 090 G34 | FI MD 080, 090 | G 3/4” | 80,0 | 343,0 | 31,0 | 92,0 | 66,0 | 315 | 27 | 5,10 |
FI MD GEH N 170 190 G114 | FI MD 170, 190 | G 1.1/4” | 110,0 | 257,0 | 32,0 | 142,0 | 109,0 | 210 | 27 | 8,50 |
FI MD GEH N 240 260 G114 | FI MD 240, 260 | G 1.1/4” | 110,0 | 371,0 | 32,0 | 142,0 | 109,0 | 210 | 30 | 15,30 |
BD = Working pressure
Ordering information
Filter element is not included. Please order separately.
Accessories
- HK VA PIS M
- Clogging indicator mechanical
- HK VA PIS EL
- Clogging indicator electrical
Spare part for following products
- FI MD 315
- Medium pressure filter 315 bar
Additional elements
- FI HD E MA
- Filter element for high-pressure filter MA
Disclaimer
Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.