FI SG E MP
Filter element for suction filter MPProduct image
Properties
Design |
without bypass valve |
Temp. min. |
-25 °C |
Temp. max. |
110 °C |
Material |
Gasket: NBR |
Operating pressure |
max. 12 bar |
Filter material |
Wire mesh |
Description
These filters protect hydraulic pumps from coarse dirt from the tank. They are flush-mounted the tank.
Item
Sort upwards
Sort downwards
Identification | Filter mesh size (μm) |
Filter area (cm2) |
Qmax (L/min) |
G1 | L (mm) |
Ø B (mm) |
AF (mm) |
Weight (kg) |
---|---|---|---|---|---|---|---|---|
FI SG E MP 0078 M90 | 90 | 290 | 20 | G 3/8” | 79,0 | 52,0 | 30 | 0,16 |
FI SG E MP 0078 M90 1/2 | 90 | 290 | 28 | G 1/2” | 79,0 | 52,0 | 30 | 0,16 |
FI SG E MP 0095 M90 1/2 | 90 | 470 | 28 | G 1/2” | 95,0 | 70,0 | 41 | 0,16 |
FI SG E MP 0095 M90 3/4 | 90 | 470 | 66 | G 3/4” | 95,0 | 70,0 | 41 | 0,22 |
FI SG E MP 0135 M90 11/4 | 90 | 1046 | 170 | G 1.1/4” | 137,0 | 99,0 | 69 | 0,47 |
FI SG E MP 0135 M90 11/2 | 90 | 1046 | 170 | G 1.1/2” | 137,0 | 99,0 | 69 | 0,47 |
FI SG E MP 0140 M90 3/4 | 90 | 720 | 66 | G 3/4” | 141,0 | 70,0 | 41 | 0,30 |
FI SG E MP 0140 M90 1 | 90 | 720 | 130 | G 1" | 141,0 | 70,0 | 41 | 0,30 |
FI SG E MP 0140 M250 1 | 250 | 720 | 900 | G 1" | 141,0 | 70,0 | 41 | 0,30 |
FI SG E MP 0140 M90 11/2 | 90 | 2000 | 250 | G 1.1/2” | 160,0 | 130,0 | 70 | 0,84 |
FI SG E MP 0140 M90 2 | 90 | 2000 | 470 | G 2" | 160,0 | 130,0 | 70 | 0,84 |
FI SG E MP 0225 M90 11/4 | 90 | 1850 | 170 | G 1.1/4” | 227,0 | 99,0 | 69 | 0,68 |
FI SG E MP 0225 M90 11/2 | 90 | 1850 | 250 | G 1.1/2” | 227,0 | 99,0 | 69 | 0,68 |
FI SG E MP 0225 M90 2 | 90 | 1850 | 470 | G 2" | 227,0 | 99,0 | 69 | 0,68 |
FI SG E MP 0262 M90 2 | 90 | 3550 | 470 | G 2" | 262,0 | 130,0 | 69 | 1,25 |
FI SG E MP 0270 M90 21/2 | 90 | 3550 | 840 | G 2.1/2" -11 | 272,0 | 130,0 | 101 | 1,25 |
FI SG E MP 0270 M90 3 | 90 | 3620 | 980 | G 3" -11 | 272,0 | 130,0 | 101 | 1,25 |
FI SG E MP 0330 M90 3 | 90 | 4160 | 980 | G 3" -11 | 330,0 | 130,0 | 101 | 1,30 |
Qmax - max intake volumetric flow
Ordering information
Available on request: Other filter mesh sizes, other threads, filter with bypass or magnet
Disclaimer
Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.