FI SP R 3

Spin-on return flow filter type 3
Hide product imageProduct image
FI SP R 3 data/img/product/HK_MPS_300_Zeichnung.jpg - FI SP R 3
Hide propertiesProperties
Design as return filter
with bypass valve 1.75 bar, without clogging indicator
Temp. min. -25 °C
Temp. max. 110 °C
Material Filter head in aluminum
Gasket: NBR
Operating pressure max. 12 bar
Filter mesh size 10 μm
Hide descriptionDescription

Spin-on filters for pipeline installation
Pressure differential for paper filter element (P) max. 4 bar
Pressure differential for filter inorganic element (A) max. 4 bar
Design (Qmax.) for medium ISO VG 46
at 50°C (30 mm2/s) at Δptot = 0.4 bar

Hide informationNote

For utilization as a suction filter a suction filter head FI SP S FK *** must be used.

Hide product tableItem

Sort upwards

Sort downwards

Qmax - max intake volumetric flow 

Hide ordering informationOrdering information

Other filter materials and filters for other types of oil, viscosities or temperatures available on request

Hide product accessoriesAccessories
HK VA MAN
Clogging indicator pressure gauge
Hide product spare partsSpare parts
FI SP E MP
Filter element for spin-on filter MP
FI SP R/S FK
Filter head for spin-on return flow filter / suction filter
Disclaimer

Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.