GVM 90
Rotary fitting, angle 90°, friction bearingProduct image
Properties
Connection 1 |
metric cylindrical outer thread |
Sealing form 1 |
Shape E |
Connection 2 |
metric cylindrical outer thread |
Sealing form 2 |
24° inner cone |
Design |
Rotary fitting (screw-in connector) |
Construction type |
Friction bearing |
Construction |
Angle 90° |
Scope of supply |
Socket (without union nut and cutting ring) |
Material |
Steel |
Surface |
electro galvanised |
Note
Information about fitting, installation, pressure loads and permissible operating temperatures can be found in the technical information for pipe fittings.
Item
Sort upwards
Sort downwards
Identification | Series | Operating pressure | Ø d2 (mm) |
G1 | d3 (mm) |
i (mm) |
L1 (mm) |
L2 (mm) |
L4 (mm) |
L5 (mm) |
AF (mm) |
S1 | S2 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GVM 90 NW 04 HL 14 | L | PN 40 | 6 | M 14 x 1.5 | 19 | 12 | 20,0 | 18,0 | 27 | 12,0 | 12 | 19 | 14 |
GVM 90 NW 08 HL 18 | L | PN 40 | 10 | M 18 x 1.5 | 24 | 12 | 26,0 | 18,0 | 30 | 15,0 | 14 | 24 | 19 |
GVM 90 NW 10 HL 22 | L | PN 40 | 12 | M 22 x 1.5 | 27 | 14 | 27,0 | 21,0 | 32 | 17,0 | 17 | 27 | 22 |
GVM 90 NW 13 HL 27 | L | PN 40 | 15 | M 27 x 2 | 32 | 16 | 33,0 | 24,0 | 36 | 21,0 | 19 | 32 | 27 |
GVM 90 NW 16 HL 33 | L | PN 40 | 18 | M 33 x 2 | 40 | 18 | 37,5 | 27,5 | 40 | 23,5 | 27 | 41 | 32 |
GVM 90 NW 20 HL 33 | L | PN 40 | 22 | M 33 x 2 | 40 | 18 | 39,5 | 27,5 | 44 | 27,5 | 27 | 41 | 36 |
GVM 90 NW 25 HL 42 | L | PN 40 | 28 | M 42 x 2 | 50 | 20 | 44,0 | 31,0 | 47 | 30,5 | 36 | 50 | 41 |
GVM 90 NW 32 HL 48 | L | PN 40 | 35 | M 48 x 2 | 55 | 22 | 54,0 | 35,0 | 56 | 34,5 | 41 | 55 | 50 |
GVM 90 NW 03 HS 14 | S | PN 100 | 6 | M 14 x 1.5 | 19 | 12 | 21,0 | 18,0 | 31 | 16,0 | 12 | 19 | 17 |
GVM 90 NW 06 HS 18 | S | PN 100 | 10 | M 18 x 1.5 | 24 | 12 | 27,0 | 18,0 | 34 | 17,5 | 17 | 24 | 22 |
GVM 90 NW 08 HS | S | PN 100 | 12 | M 18 x 1.5 | 27 | 14 | 28,0 | 21,0 | 38 | 21,5 | 17 | 27 | 24 |
GVM 90 NW 08 HS 22 | S | PN 100 | 12 | M 22 x 1.5 | 27 | 14 | 28,0 | 32,0 | 38 | 21,5 | 17 | 27 | 24 |
GVM 90 NW 13 HS 27 | S | PN 100 | 16 | M 27 x 2 | 32 | 16 | 34,0 | 24,0 | 43 | 24,5 | 24 | 32 | 30 |
GVM 90 NW 16 HS 33 | S | PN 100 | 20 | M 33 x 2 | 40 | 18 | 39,5 | 27,5 | 48 | 26,5 | 27 | 41 | 36 |
GVM 90 NW 20 HS | S | PN 100 | 25 | M 33 x 2 | 40 | 18 | 42,5 | 27,5 | 54 | 30,0 | 36 | 41 | 46 |
GVM 90 NW 25 HS | S | PN 100 | 30 | M 42 x 2 | 50 | 20 | 48,0 | 31,0 | 62 | 35,5 | 41 | 50 | 50 |
GVM 90 NW 32 HS | S | PN 100 | 38 | M 48 x 2 | 55 | 22 | 55,0 | 35,0 | 72 | 41,0 | 50 | 55 | 60 |
Series: LL = Very light L = Light S = Heavy – PN = Nominal pressure PB = Max. operating pressure – Ø d2 = External pipe diameter
Disclaimer
Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.