HK DPH 4
Directional control valve NG25Product image
Properties
Design |
4/3-way valve (without pilot valve) pilot-controlled |
Operating pressure |
P, A, B: max. 350bar / T: max. 210bar |
Volumetric flow |
max. 650 l/min (note characteristic curves) |
Connection |
ISO/Cetop 08 NG25 |
Mounting |
6 No. hex. socket head screw M12x50 12.9 |
Description
These valves are actuated by a leak oil-reduced, solenoid-operated directional control valve size 6 set up as a pilot valve (type HK DHE *P*).
Control is internal, but conversion to external is possible.
The minimum control pressure for correct functioning is 8 bar.
With the version with the control pressure generator, an additional pressure drop occurs, which ensures the minimum required control pressure for correct functioning. The version with the control pressure generator must be used if the pressure drop in the valve is below the minimum control pressure.
Item
Sort upwards
Sort downwards
Identification | Circuit diagram | Type | Overlap | Piston type | Design | Weight (kg) |
---|---|---|---|---|---|---|
HK DPH 4 710 DR SPIL | 4/3 | negative (open) | 0 [PB/AT]-[ABPT]-[PA/BT] | Spring return, control pressure generator | 12,2 | |
HK DPH 4 711 D SPIL | 4/3 | positive (closed) | 1 [PB/AT]-[A/B/P/T]-[PA/BT] | Spring return | 12,2 | |
HK DPH 4 713 D SPIL | 4/3 | positive (closed) | 3 [PB/AT]-[ABT/P]-[PA/BT] | Spring return | 12,2 | |
HK DPH 4 714 DR SPIL | 4/3 | negative (open) | 4 [PA/BT]-[A/B/PT]-[PB/AT] | Spring return, control pressure generator | 12,2 |
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]
Ordering information
Further circuits and versions, volumetric flows and switching power limits on request
Accessories
- HK DHE X 00 DC
- Solenoid-operated directional control valve size 6 without coil
- HK DHE X 00 AC
- Solenoid-operated directional control valve size 6 without coil
- HK M HK DPH 4
- Set of bolts for NG25 valves type HK DPH 4
Disclaimer
Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.