![HFM SKE 12 HFM SKE 12](/data/img/category/HFM_SKE_Foto.jpg)
HFM SKE 12
Measuring hose line- Application
-
Measuring equipment
- Design
-
Hose line DN 2 with M 12.65 x 1.5 measuring connections
- Inner layer
-
Polyamide
- Insert
-
one aramide braided insert
- Outer layer
-
Polyurethane
- Scope of supply
-
with dust protection
- Temp. min.
-
-20 °C
- Temp. max.
-
100 °C
- Media
-
Liquids based on mineral oil and glycol
![HFM SKE 16 HFM SKE 16](/data/img/category/HFM_SKE_Foto.jpg)
HFM SKE 16
Measuring hose line- Application
-
Measuring equipment
- Design
-
Hose line DN 2 with M 16 x 1.5 measuring connections
- Inner layer
-
Polyamide
- Insert
-
one aramide braided insert
- Outer layer
-
Polyurethane
- Scope of supply
-
with dust protection
- Temp. min.
-
-20 °C
- Temp. max.
-
100 °C
- Media
-
Liquids based on mineral oil and glycol
![HFM SKE HFM SKE](/data/img/category/HFM_SKE_Foto.jpg)
HFM SKE
Measuring hose line- Application
-
Measuring equipment
- Design
-
Hose line DN 2 with M 16 x 2 measuring connections
- Inner layer
-
Polyamide
- Insert
-
one aramide braided insert
- Outer layer
-
Polyurethane
- Scope of supply
-
with dust protection
- Temp. min.
-
-20 °C
- Temp. max.
-
100 °C
- Media
-
Liquids based on mineral oil and glycol
![HFM SKE VA HFM SKE VA](/data/img/category/HFM_SKE_VA_Foto.jpg)
HFM SKE VA
Measuring hose line- Application
-
Measuring equipment
- Design
-
Hose line DN 2 with M 16 x 2 measuring connections
- Inner layer
-
Polyamide
- Insert
-
one aramide braided insert
- Outer layer
-
Polyurethane
- Scope of supply
-
with dust protection
- Temp. min.
-
-20 °C
- Temp. max.
-
100 °C
- Media
-
Liquids based on mineral oil and glycol
![HFM MK ST HFM MK ST](/data/img/category/HFM_MK400_S_Foto.jpg)
HFM MK ST
Measuring hose line- Application
-
Measuring equipment
- Design
-
Hose line DN 2 with plug-in measuring connections
- Inner layer
-
Polyamide
- Insert
-
one aramide braided insert
- Outer layer
-
Polyurethane
- Scope of supply
-
with dust protection
- Temp. min.
-
-20 °C
- Temp. max.
-
100 °C
- Media
-
Liquids based on mineral oil and glycol
![HFM ADA HFM ADA](/data/img/category/HF_ADA_Foto.jpg)
HFM ADA
Measuring hose line- Application
-
Measuring equipment
- Design
-
Hose line DN 2 with measuring connections M 16 x 2 and plug-in
- Inner layer
-
Polyamide
- Insert
-
one aramide braided insert
- Outer layer
-
Polyurethane
- Scope of supply
-
with dust protection
- Temp. min.
-
-20 °C
- Temp. max.
-
100 °C
- Media
-
Liquids based on mineral oil and glycol