K-WTEH 3-TEILIG HANSA PRO
3-part service unit, with manual/semi-automatic condensate drain and pressure gauge, HANSA PROPhoto du produit
Caractéristiques
Pression en sortie |
Pa 0,5 - 8 bar (Standart) Pa 0,1 - 1 bar Pa 0,1 - 2 bar Pa 0,2 - 4 bar Pa 0,5 - 10 bar Pa 0,5 - 16 bar |
Température de fluide |
-10 °C to +50 °C |
Température ambiante |
-10 °C to +50 °C |
Médiums |
Air comprimé |
Construction |
Centrifugal filter membrane pressure regulator with relieving, fog lubricator |
Mode de fixation |
Line mounting, panel mounting, mounting kit or wall mounting |
Actionnement / protection |
lockable handwheel |
Position de montage |
Vertical, drain down |
Finesse du filtre |
5,00 μm |
Raccord de manomètre |
G 1/4 i |
Quantité de condensat maxi |
49 cc |
Plein d'huile maxi |
80 cc |
Débit nominal G 1/2 |
3.500 l/min (P1 = 10 bar, P2 = 6,3 bar/Delta P = 1 bar) |
Débit nominal G 3/8 |
3.500 l/min (P1 = 10 bar, P2 = 6,3 bar/Delta P = 1 bar) |
Dosage d'huile à qv=1000 l/min |
1-2 drops / min (guideline) |
PE maxi 12 |
16 bar |
Élément de filtre |
Cellpor |
Boîtier |
PA66 |
Membrane, joints d'étanchéité |
Ms/NBR/PA6 |
Embout compte-goutte |
Polycarbonate |
Type d'huile |
CL 32 acc. to DIN 51517 - ISO VG 32 |
Article
classer par ordre croissant
classer par ordre décroissant
Désignation | Raccord | Plage de régulation | Zones d'affichage | Réservoir | Gabarit | Évacuation du condensat |
---|---|---|---|---|---|---|
K- 07 25 22 12 | G 3/8 i | 0.1 - 1 bar | 0 - 1,6 bar | polycarbonate with protective cage | 2 | manual / semi-automatic |
K- 07 25 22 13 | G 3/8 i | 0.1 - 2 bar | 0 - 2,5 bar | polycarbonate with protective cage | 2 | manual / semi-automatic |
K- 07 25 22 14 | G 3/8 i | 0.2 - 4 bar | 0 - 6 bar | polycarbonate with protective cage | 2 | manual / semi-automatic |
K- 07 25 22 15 | G 3/8 i | 0.5 - 8 bar | 0 - 10 bar | polycarbonate with protective cage | 2 | manual / semi-automatic |
K- 07 25 22 16 | G 3/8 i | 0.5 - 10 bar | 0 - 16 bar | polycarbonate with protective cage | 2 | manual / semi-automatic |
K- 07 25 22 17 | G 3/8 i | 0.5 - 16 bar | 0 - 25 bar | polycarbonate with protective cage | 2 | manual / semi-automatic |
K- 07 25 22 18 | G 1/2 i | 0.1 - 1 bar | 0 - 1,6 bar | polycarbonate with protective cage | 2 | manual / semi-automatic |
K- 07 25 22 19 | G 1/2 i | 0.1 - 2 bar | 0 - 2,5 bar | polycarbonate with protective cage | 2 | manual / semi-automatic |
K- 07 25 22 20 | G 1/2 i | 0.2 - 4 bar | 0 - 6 bar | polycarbonate with protective cage | 2 | manual / semi-automatic |
K- 07 25 22 21 | G 1/2 i | 0.5 - 8 bar | 0 - 10 bar | polycarbonate with protective cage | 2 | manual / semi-automatic |
K- 07 25 22 22 | G 1/2 i | 0.5 - 10 bar | 0 - 16 bar | polycarbonate with protective cage | 2 | manual / semi-automatic |
K- 07 25 22 23 | G 1/2 i | 0.5 - 16 bar | 0 - 25 bar | polycarbonate with protective cage | 2 | manual / semi-automatic |
K- 07 25 22 24 | G 3/8 i | 0.1 - 1 bar | 0 - 1,6 bar | zinc with visual display | 2 | manual / semi-automatic |
K- 07 25 22 25 | G 3/8 i | 0.1 - 2 bar | 0 - 2,5 bar | zinc with visual display | 2 | manual / semi-automatic |
K- 07 25 22 26 | G 3/8 i | 0.2 - 4 bar | 0 - 6 bar | zinc with visual display | 2 | manual / semi-automatic |
K- 07 25 22 27 | G 3/8 i | 0.5 - 8 bar | 0 - 10 bar | zinc with visual display | 2 | manual / semi-automatic |
K- 07 25 22 28 | G 3/8 i | 0.5 - 10 bar | 0 - 16 bar | zinc with visual display | 2 | manual / semi-automatic |
K- 07 25 22 29 | G 3/8 i | 0.5 - 16 bar | 0 - 25 bar | zinc with visual display | 2 | manual / semi-automatic |
K- 07 25 22 30 | G 1/2 i | 0.1 - 1 bar | 0 - 1,6 bar | zinc with visual display | 2 | manual / semi-automatic |
K- 07 25 22 31 | G 1/2 i | 0.1 - 2 bar | 0 - 2,5 bar | zinc with visual display | 2 | manual / semi-automatic |
K- 07 25 22 32 | G 1/2 i | 0.2 - 4 bar | 0 - 6 bar | zinc with visual display | 2 | manual / semi-automatic |
K- 07 25 22 33 | G 1/2 i | 0.5 - 8 bar | 0 - 10 bar | zinc with visual display | 2 | manual / semi-automatic |
K- 07 25 22 34 | G 1/2 i | 0.5 - 10 bar | 0 - 16 bar | zinc with visual display | 2 | manual / semi-automatic |
K- 07 25 22 35 | G 1/2 i | 0.5 - 16 bar | 0 - 25 bar | zinc with visual display | 2 | manual / semi-automatic |
Clause de non-responsabilité
En dépit du soin apporté aux vérifications, nous ne pouvons garantir une absence totale d'erreur et ne saurions être tenus responsables des indications contenues.
Toutes les indications figurant dans notre catalogue en ligne se basent sur les normes actuellement en vigueur et sur les prescriptions des associations professionnelles. La sécurité du produit n'est pas garantie en cas de non respect des instructions de montage. Le non respect des instructions mentionnées est susceptible de nuire à la sûreté de fonctionnement du produit et d'annuler notre garantie. En tout état de cause, notre garantie ne s'applique qu'aux produits HANSA-FLEX. Nos produits bénéficient de mises au point permanentes et peuvent donc être soumis à des modifications techniques.