HK DG4V3
Solenoid-operated directional control valve NG6
Product image


Properties
Design |
4/2-way valve or 4/3-way valve with manual emergency operation |
Scope of supply |
with coil, without plug |
Operating pressure |
P, A, B: max. 350bar / T: max. 210bar |
Volumetric flow |
max. 80 l/min (note characteristic curves) |
Connection |
ISO/Cetop 03 size 6 |
Mounting |
4 pcs. socket head screw M5x30 12.9 |
protection class |
IP 65 |
Description
switching capacity limits see characteristic curves
Item

Sort upwards
Sort downwards
![]() |
Circuit diagram | Type | Piston type | Rated voltage/ current type |
Overlap | Design | Weight (kg) |
---|---|---|---|---|---|---|---|
HK DG4V3 0A VM U 12DC | ![]() ![]() |
4/2 | 0A [PB/AT]-[PA/BT] | 12 VDC | negative (open) | Spring return | 1,60 |
HK DG4V3 0A VM U 24DC | ![]() ![]() |
4/2 | 0A [PB/AT]-[PA/BT] | 24 VDC | negative (open) | Spring return | 1,60 |
HK DG4V3 0A VM U 110AC | ![]() ![]() |
4/2 | 0A [PB/AT]-[PA/BT] | 110 VAC | negative (open) | Spring return | 1,60 |
HK DG4V3 0A VM U 230AC | ![]() ![]() |
4/2 | 0A [PB/AT]-[PA/BT] | 230 VAC 50 Hz | negative (open) | Spring return | 1,60 |
HK DG4V3 0B VM U 12DC | ![]() ![]() |
4/2 | 0B [PB/AT]-[ABPT] | 12 VDC | negative (open) | Spring return | 1,60 |
HK DG4V3 0B VM U 24DC | ![]() ![]() |
4/2 | 0B [PB/AT]-[ABPT] | 24 VDC | negative (open) | Spring return | 1,60 |
HK DG4V3 0B VM U 110AC | ![]() ![]() |
4/2 | 0B [PB/AT]-[ABPT] | 110 VAC | negative (open) | Spring return | 1,60 |
HK DG4V3 0B VM U 230AC | ![]() ![]() |
4/2 | 0B [PB/AT]-[ABPT] | 230 VAC 50 Hz | negative (open) | Spring return | 1,60 |
HK DG4V3 2A VM U 12DC | ![]() ![]() |
4/2 | 2A [PB/AT]-[PA/BT] | 12 VDC | positive (closed) | Spring return | 1,60 |
HK DG4V3 2A VM U 24DC | ![]() ![]() |
4/2 | 2A [PB/AT]-[PA/BT] | 24 VDC | positive (closed) | Spring return | 1,60 |
HK DG4V3 2A VM U 110AC | ![]() ![]() |
4/2 | 2A [PB/AT]-[PA/BT] | 110 VAC | positive (closed) | Spring return | 1,60 |
HK DG4V3 2A VM U 230AC | ![]() ![]() |
4/2 | 2A [PB/AT]-[PA/BT] | 230 VAC 50 Hz | positive (closed) | Spring return | 1,60 |
HK DG4V3 2AL VM U 12DC | ![]() ![]() |
4/2 | 2AL [PB/AT]-[PA/BT] | 12 VDC | positive (closed) | Spring return | 1,60 |
HK DG4V3 2AL VM U 24DC | ![]() ![]() |
4/2 | 2AL [PB/AT]-[PA/BT] | 24 VDC | positive (closed) | Spring return | 1,60 |
HK DG4V3 2AL VM U 110AC | ![]() ![]() |
4/2 | 2AL [PB/AT]-[PA/BT] | 110 VAC | positive (closed) | Spring return | 1,60 |
HK DG4V3 2AL VM U 230AC | ![]() ![]() |
4/2 | 2AL [PB/AT]-[PA/BT] | 230 VAC 50 Hz | positive (closed) | Spring return | 1,60 |
HK DG4V3 2B VM U 12DC | ![]() ![]() |
4/2 | 2B [PB/AT]-[A/B/P/T] | 12 VDC | positive (closed) | Spring return | 1,60 |
HK DG4V3 2B VM U 24DC | ![]() ![]() |
4/2 | 2B [PB/AT]-[A/B/P/T] | 24 VDC | positive (closed) | Spring return | 1,60 |
HK DG4V3 2B VM U 110AC | ![]() ![]() |
4/2 | 2B [PB/AT]-[A/B/P/T] | 110 VAC | positive (closed) | Spring return | 1,60 |
HK DG4V3 2B VM U 230AC | ![]() ![]() |
4/2 | 2B [PB/AT]-[A/B/P/T] | 230 VAC 50 Hz | positive (closed) | Spring return | 1,60 |
HK DG4V3 6B VM U 12DC | ![]() ![]() |
4/2 | 6B [PB/AT]-[ABT/P] | 12 VDC | positive (closed) | Spring return | 1,60 |
HK DG4V3 6B VM U 24DC | ![]() ![]() |
4/2 | 6B [PB/AT]-[ABT/P] | 24 VDC | positive (closed) | Spring return | 1,60 |
HK DG4V3 6B VM U 110AC | ![]() ![]() |
4/2 | 6B [PB/AT]-[ABT/P] | 110 VAC | positive (closed) | Spring return | 1,60 |
HK DG4V3 6B VM U 230AC | ![]() ![]() |
4/2 | 6B [PB/AT]-[ABT/P] | 230 VAC 50 Hz | positive (closed) | Spring return | 1,60 |
HK DG4V3 8BL VM U 12DC | ![]() ![]() |
4/2 | 8BL [PA/BT]-[A/B/PT] | 12 VDC | negative (open) | Spring return | 1,60 |
HK DG4V3 8BL VM U 24DC | ![]() ![]() |
4/2 | 8BL [PA/BT]-[A/B/PT] | 24 VDC | negative (open) | Spring return | 1,60 |
HK DG4V3 8BL VM U 110AC | ![]() ![]() |
4/2 | 8BL [PA/BT]-[A/B/PT] | 110 VAC | negative (open) | Spring return | 1,60 |
HK DG4V3 8BL VM U 230AC | ![]() ![]() |
4/2 | 8BL [PA/BT]-[A/B/PT] | 230 VAC 50 Hz | negative (open) | Spring return | 1,60 |
HK DG4V3 22A VM U 12DC | ![]() ![]() |
4/2 | 22A [PB/A/T]-[PA/B/T] | 12 VDC | positive (closed) | Spring return | 1,60 |
HK DG4V3 22A VM U 24DC | ![]() ![]() |
4/2 | 22A [PB/A/T]-[PA/B/T] | 24 VDC | positive (closed) | Spring return | 1,60 |
HK DG4V3 22A VM U 110AC | ![]() ![]() |
4/2 | 22A [PB/A/T]-[PA/B/T] | 110 VAC | positive (closed) | Spring return | 1,60 |
HK DG4V3 22A VM U 230AC | ![]() ![]() |
4/2 | 22A [PB/A/T]-[PA/B/T] | 230 VAC 50 Hz | positive (closed) | Spring return | 1,60 |
HK DG4V3 0C VM U 12DC | ![]() ![]() |
4/3 | 0C [PB/AT]-[ABPT]-[PA/BT] | 12 VDC | negative (open) | spring return to 0 | 2,20 |
HK DG4V3 0C VM U 24DC | ![]() ![]() |
4/3 | 0C [PB/AT]-[ABPT]-[PA/BT] | 24 VDC | negative (open) | spring return to 0 | 2,20 |
HK DG4V3 0C VM U 110AC | ![]() ![]() |
4/3 | 0C [PB/AT]-[ABPT]-[PA/BT] | 110 VAC | negative (open) | spring return to 0 | 2,20 |
HK DG4V3 0C VM U 230AC | ![]() ![]() |
4/3 | 0C [PB/AT]-[ABPT]-[PA/BT] | 230 VAC 50 Hz | negative (open) | spring return to 0 | 2,20 |
HK DG4V3 2C VM U 12DC | ![]() ![]() |
4/3 | 2C [PB/AT]-[A/B/P/T]-[PA/BT] | 12 VDC | positive (closed) | spring return to 0 | 2,20 |
HK DG4V3 2C VM U 24DC | ![]() ![]() |
4/3 | 2C [PB/AT]-[A/B/P/T]-[PA/BT] | 24 VDC | positive (closed) | spring return to 0 | 2,20 |
HK DG4V3 2C VM U 110AC | ![]() ![]() |
4/3 | 2C [PB/AT]-[A/B/P/T]-[PA/BT] | 110 VAC | positive (closed) | spring return to 0 | 2,20 |
HK DG4V3 2C VM U 230AC | ![]() ![]() |
4/3 | 2C [PB/AT]-[A/B/P/T]-[PA/BT] | 230 VAC 50 Hz | positive (closed) | spring return to 0 | 2,20 |
HK DG4V3 6C VM U 12DC | ![]() ![]() |
4/3 | 6C [PB/AT]-[ABT/P]-[PA/BT] | 12 VDC | positive (closed) | spring return to 0 | 2,20 |
HK DG4V3 6C VM U 24DC | ![]() ![]() |
4/3 | 6C [PB/AT]-[ABT/P]-[PA/BT] | 24 VDC | positive (closed) | spring return to 0 | 2,20 |
HK DG4V3 6C VM U 110AC | ![]() ![]() |
4/3 | 6C [PB/AT]-[ABT/P]-[PA/BT] | 110 VAC | positive (closed) | spring return to 0 | 2,20 |
HK DG4V3 6C VM U 230AC | ![]() ![]() |
4/3 | 6C [PB/AT]-[ABT/P]-[PA/BT] | 230 VAC 50 Hz | positive (closed) | spring return to 0 | 2,20 |
HK DG4V3 7C VM U 12DC | ![]() ![]() |
4/3 | 7C [PB/AT]-[PAB/T]-[PA/BT] | 12 VDC | positive (closed) | spring return to 0 | 2,20 |
HK DG4V3 7C VM U 24DC | ![]() ![]() |
4/3 | 7C [PB/AT]-[PAB/T]-[PA/BT] | 24 VDC | positive (closed) | spring return to 0 | 2,20 |
HK DG4V3 7C VM U 110AC | ![]() ![]() |
4/3 | 7C [PB/AT]-[PAB/T]-[PA/BT] | 110 VAC | positive (closed) | spring return to 0 | 2,20 |
HK DG4V3 7C VM U 230AC | ![]() ![]() |
4/3 | 7C [PB/AT]-[PAB/T]-[PA/BT] | 230 VAC 50 Hz | positive (closed) | spring return to 0 | 2,20 |
HK DG4V3 8C VM U 12DC | ![]() ![]() |
4/3 | 8C [PA/BT]-[A/B/PT]-[PB/AT] | 12 VDC | negative (open) | spring return to 0 | 2,20 |
HK DG4V3 8C VMU 24DC | ![]() ![]() |
4/3 | 8C [PA/BT]-[A/B/PT]-[PB/AT] | 24 VDC | negative (open) | spring return to 0 | 2,20 |
HK DG4V3 8C VM U 110AC | ![]() ![]() |
4/3 | 8C [PA/BT]-[A/B/PT]-[PB/AT] | 110 VAC | negative (open) | spring return to 0 | 2,20 |
HK DG4V3 8C VM U 230AC | ![]() ![]() |
4/3 | 8C [PA/BT]-[A/B/PT]-[PB/AT] | 230 VAC 50 Hz | negative (open) | spring return to 0 | 2,20 |
HK DG4V3 2N VM U 12DC | ![]() ![]() |
4/2 | 2N [PB/AT]-[PA/BT] | 12 VDC | positive (closed) | 2 latching positions | 1,60 |
HK DG4V3 2N VM U 24DC | ![]() ![]() |
4/2 | 2N [PB/AT]-[PA/BT] | 24 VDC | positive (closed) | 2 latching positions | 1,60 |
HK DG4V3 2N VM U 110AC | ![]() ![]() |
4/2 | 2N [PB/AT]-[PA/BT] | 110 VAC | positive (closed) | 2 latching positions | 1,60 |
HK DG4V3 2N VM U 230AC | ![]() ![]() |
4/2 | 2N [PB/AT]-[PA/BT] | 230 VAC 50 Hz | positive (closed) | 2 latching positions | 1,60 |
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]
Ordering information
Further circuits and versions, volumetric flows and switching power limits on request
Accessories

- HK SP DG4V3
- Coil for HK DG4V3 solenoid-operated valve
- HK SP DIN 43650
- Electrical plug for solenoid coil DIN 43650 / ISO 4400
- HK M HK DH
- Screw set for NG 6 valves type HK DH / DG4V3
Disclaimer
Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.