HK DLEH
Poppet valve NG 6
Product image


Properties
Scope of supply |
with coil, 24 DC without plug |
Operating pressure |
P, A, B: max. 350bar / T: max. 210bar |
Volumetric flow |
max. 30 l/min (note characteristic curves) |
Connection |
ISO/Cetop 03 size 6 |
Mounting |
4 pcs. socket head screw M5x50 12.9 |
Description
2-way or 3-way seat valves with 2 switching positions
Solenoids and all moving parts switch internally in oil
Solenoid coil 24 VDC with emergency hand operation
Item

Sort upwards
Sort downwards
![]() |
Circuit diagram | Type | Volumetric flow max. (L/min) |
Design | Weight (kg) |
---|---|---|---|---|---|
HK DLEH 2A X 24DC | ![]() ![]() |
2/2 | 12,0 | power-off open | 1,5 |
HK DLEH 2C X 24DC | ![]() ![]() |
2/2 | 12,0 | power-off closed | 1,5 |
HK DLEH 3A X 24DC | ![]() ![]() |
3/2 | 12,0 | power-off open | 1,5 |
HK DLEH 3C X 24DC | ![]() ![]() |
3/2 | 12,0 | power-off closed | 1,5 |
HK DLEHM 3A X 24DC | ![]() ![]() |
3/2 | 30,0 | power-off open | 1,7 |
HK DLEHM 3C X 24DC | ![]() ![]() |
3/2 | 30,0 | power-off closed | 1,7 |
Accessories

- HK SP DIN 43650
- Electrical plug for solenoid coil DIN 43650 / ISO 4400
- HK M HK DH
- Screw set for NG 6 valves type HK DH / DG4V3
Disclaimer
Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.