HK OLM C
Diaphragm accumulator, connection CProduct image
Properties
Connections |
Oil side type C - female thread and male thread |
Design |
Vertical installation position, gas side top |
Operating pressure |
max. 350 bar |
Temp. range |
Typ 1: -10 °C to +80 °C Typ 2: -30 °C to +110 °C |
Material |
Diaphragm: NBR standard version |
Note
Betriebsdruck 100 bis 350 bar, min. Betriebsdruck muss 10 % über Gasfülldruck liegen, max. Gasfülldruck 130 bar
CE mark for diaphragm accumulators >1.0 l gas volume
Item
Sort upwards
Sort downwards
Identification | Type | Gas volume l (L) |
p max. (bar) |
pma: p0 | pmax - pmin (bar) |
A (mm) |
B (mm) |
Ø D (mm) |
F | AF (mm) |
Weight (kg) |
---|---|---|---|---|---|---|---|---|---|---|---|
HK OLM 0.5 210 C | 1 | 0,500 | 210 | 8:1 | 175 | 163 | 33 | 106 | G 1/2” | 41 | 2,0 |
HK OLM 0.75 210 C | 1 | 0,750 | 210 | 8:1 | 175 | 180 | 33 | 124 | G 1/2” | 41 | 2,9 |
HK OLM 0.75 210 ECO C | 2 | 0,750 | 210 | 8:1 | 175 | 180 | 33 | 124 | G 1/2” | 41 | 2,9 |
HK OLM 0.75 350 ECO C | 2 | 0,750 | 350 | 8:1 | 150 | 169 | 18 | 131 | G 1/2” | 41 | 3,5 |
HK OLM 1.0 210 C | 1 | 1,000 | 210 | 8:1 | 170 | 191 | 33 | 136 | G 1/2” | 41 | 3,5 |
HK OLM 1.4 140 C | 1 | 1,400 | 140 | 8:1 | 120 | 202 | 33 | 147 | G 1/2” | 41 | 4,2 |
HK OLM 1.4 210 C | 1 | 1,400 | 210 | 8:1 | 120 | 202 | 33 | 148 | G 1/2” | 41 | 4,2 |
HK OLM 1.4 210 ECO C | 2 | 1,400 | 210 | 8:1 | 120 | 202 | 33 | 148 | G 1/2” | 41 | 4,2 |
HK OLM 1.4 350 ECO C | 2 | 1,400 | 350 | 8:1 | 150 | 220 | 33 | 160 | G 1/2” | 41 | 7,0 |
Typ 1: Standard – Typ 2: low temperature version – p0 = Gas charge pressure – pmax - pmin = Admissible pressure fluctuation of the accumulator
Ordering information
The accumulators will be delivered uncharged from stock. N2-chargings according to customer requirements arise separate costs.
Bei Bedarf bitte Kontermutter HK MS M33-15 mitbestellen.
Accessories
- HK ADA S
- Measuring adapter for pressure accumulator
Disclaimer
Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.