K-EINGANGSPL VENTILINSEL HDM
Input plates for HDM valve terminal- Media
-
Filtered, unlubricated or lubricated compressed air. If lubrication is used, it must be continuous.
- Working pressure
-
Max. vacuum 10 bar (external pilots), 3 to 7 bar (internal pilots as standard)
- Pilot pressure
-
3 - 7 bar
- Temp. range
-
-10 °C to +60 °C
- Flow rate
-
200 Nl/min (Ø 4), 500 Nl/min (Ø 6), 800 Nl/min (Ø 8)
- No. of pilots
-
Max. 16 (e.g. 16 spring return valves)
- Manual control
-
Latching (bistable), Monostable (non-latching) version also available on request
- Power input
-
0.6 W per pilot
- Protection IP
-
IP 65
K-VENTILSCHEIBE HDM 4
Valve discs for HDM valve terminal with 4 mm port- Media
-
Filtered, unlubricated or lubricated compressed air. If lubrication is used, it must be continuous.
- Working pressure
-
Max. vacuum 10 bar (external pilots), 3 to 7 bar (internal pilots as standard)
- Pilot pressure
-
3 - 7 bar
- Temp. range
-
-10 °C to +60 °C
- Flow rate
-
200 Nl/min (Ø 4), 500 Nl/min (Ø 6), 800 Nl/min (Ø 8)
- No. of pilots
-
Max. 16 (e.g. 16 spring return valves)
- Manual control
-
Latching (bistable), Monostable (non-latching) version also available on request
- Power input
-
0.6 W per pilot
- Protection IP
-
IP 65
K-VENTILSCHEIBE HDM 6
Valve discs for HDM valve terminal with 6 mm port- Media
-
Filtered, unlubricated or lubricated compressed air. If lubrication is used, it must be continuous.
- Working pressure
-
Max. vacuum 10 bar (external pilots), 3 to 7 bar (internal pilots as standard)
- Pilot pressure
-
3 - 7 bar
- Temp. range
-
-10 °C to +60 °C
- Flow rate
-
200 Nl/min (Ø 4), 500 Nl/min (Ø 6), 800 Nl/min (Ø 8)
- No. of pilots
-
Max. 16 (e.g. 16 spring return valves)
- Manual control
-
Latching (bistable), Monostable (non-latching) version also available on request
- Power input
-
0.6 W per pilot
- Protection IP
-
IP 65
K-VENTILSCHEIBE HDM 8
Valve discs for HDM valve terminal with 8 mm port- Media
-
Filtered, unlubricated or lubricated compressed air. If lubrication is used, it must be continuous.
- Working pressure
-
Max. vacuum 10 bar (external pilots), 3 to 7 bar (internal pilots as standard)
- Pilot pressure
-
3 - 7 bar
- Temp. range
-
-10 °C to +60 °C
- Flow rate
-
200 Nl/min (Ø 4), 500 Nl/min (Ø 6), 800 Nl/min (Ø 8)
- No. of pilots
-
Max. 16 (e.g. 16 spring return valves)
- Manual control
-
Latching (bistable), Monostable (non-latching) version also available on request
- Power input
-
0.6 W per pilot
- Protection IP
-
IP 65
K-ZFL VENTILINSEL HDM
Intermediate plates for HDM valve terminal- Media
-
Filtered, unlubricated or lubricated compressed air. If lubrication is used, it must be continuous.
- Working pressure
-
Max. vacuum 10 bar (external pilots), 3 to 7 bar (internal pilots as standard)
- Pilot pressure
-
3 - 7 bar
- Temp. range
-
-10 °C to +60 °C
- Flow rate
-
200 Nl/min (Ø 4), 500 Nl/min (Ø 6), 800 Nl/min (Ø 8)
- No. of pilots
-
Max. 16 (e.g. 16 spring return valves)
- Manual control
-
Latching (bistable), Monostable (non-latching) version also available on request
- Power input
-
0.6 W per pilot
- Protection IP
-
IP 65
K-ENDPLATTEN V
End plate for HDM valve terminal- Media
-
Filtered, unlubricated or lubricated compressed air. If lubrication is used, it must be continuous.
- Working pressure
-
Max. vacuum 10 bar (external pilots), 3 to 7 bar (internal pilots as standard)
- Pilot pressure
-
3 - 7 bar
- Temp. range
-
-10 °C to +60 °C
- Flow rate
-
200 Nl/min (Ø 4), 500 Nl/min (Ø 6), 800 Nl/min (Ø 8)
- No. of pilots
-
Max. 16 (e.g. 16 spring return valves)
- Operating principle
-
Blind (terminates the system)
- Manual control
-
Latching (bistable), Monostable (non-latching) version also available on request
- Power input
-
0.6 W per pilot
- Protection IP
-
IP 65
K-ADA HUTPROFIL
Adapter for DIN rail- Media
-
Filtered, unlubricated or lubricated compressed air. If lubrication is used, it must be continuous.
- Working pressure
-
Max. vacuum 10 bar (external pilots), 3 to 7 bar (internal pilots as standard)
- Pilot pressure
-
3 - 7 bar
- Temp. range
-
-10 °C to +60 °C
- Flow rate
-
200 Nl/min (Ø 4), 500 Nl/min (Ø 6), 800 Nl/min (Ø 8)
- No. of pilots
-
Max. 16 (e.g. 16 spring return valves)
- Manual control
-
Latching (bistable), Monostable (non-latching) version also available on request
- Power input
-
0.6 W per pilot
- Protection IP
-
IP 65
K-ELEKTRISCHE ANSCHLUESSE
Electrical connection (multi-pole, 25-pin, IP 65)- Media
-
Filtered, unlubricated or lubricated compressed air. If lubrication is used, it must be continuous.
- Working pressure
-
Max. vacuum 10 bar (external pilots), 3 to 7 bar (internal pilots as standard)
- Pilot pressure
-
3 - 7 bar
- Temp. range
-
-10 °C to +60 °C
- Flow rate
-
200 Nl/min (Ø 4), 500 Nl/min (Ø 6), 800 Nl/min (Ø 8)
- No. of pilots
-
Max. 16 (e.g. 16 spring return valves)
- Manual control
-
Latching (bistable), Monostable (non-latching) version also available on request
- Power input
-
0.6 W per pilot
- Protection IP
-
IP 65
K-ODER-VENTIL
OR valves- Operating pressure
-
2 - 10 bar
- Temp. range
-
-10 °C to +80 °C
- Flow rate at 6,3 bar and 1 bar
-
500 Nl/min (G 1/8), 1300 Nl/min (G 1/4)
- Valve body
-
Aluminium
- Ball
-
Stainless steel
- Seals
-
NBR
K-PNEU LOGIKELEMENTE
Pneumatic logic elements- Working pressure
-
OR-AND: 1.5-8 bar, NOT: 0.4-6 bar, YES - MEMORY: 0.0-8 bar (pilot pressure from 1.5-8 bar)
- Temp. range
-
-10 °C to +60 °C
- Connection
-
Push-in fitting for 4 mm pipe
- Flow rate
-
100 l/min (at 6 bar and Δp = 1 bar)
- nominal Ø
-
2,7 mm
- Reset
-
OR - AND: by compressed air, MEMORY: by air, YES - NOT: by mechanical spring
- Material
-
Technopolymer
- Slider
-
Aluminium
- Sealant
-
NBR
K-PNEU LOGIKELEMENTE TIMER
Pneumatic logic element: Timer- Working pressure
-
2.5 - 8 bar
- Pressure indication
-
Via orange pin
- Signal shut-off time
-
< 0.1 s
- Adjustment range
-
0 - 30 s (at 6 bar)
- Operating principle
-
Timer
- Reset
-
By mechanical spring
- Material
-
Anodised aluminium / technopolymer
- Internal parts
-
Brass / technopolymer
- More information
-
See logic elements