HK BFCV
3-way flow control valve BFCVProduct image
Properties
Design |
pressure-compensated |
Operating pressure |
max. 300 bar |
Description
max. deviation: 5%
Setting via setscrew
residual oil flow at outlet 2 can be pressurized.
Only adjust valves in depressurized state!
Note
These valves must be set according to the application.
Tightening torque for valve size 08 with Alu housing: 34-41 Nm
Tightening torque for valve size 08 with Steel housing: 47-54 Nm
Tightening torque for valve size 10 with Alu housing: 47-54 Nm
Tightening torque for valve size 10 with Steel housing: 74-81 Nm
Tightening torque for valve size 12 with Alu housing: 74-81 Nm
Tightening torque for valve size 12 with Steel housing: 95-102 Nm
Item
Sort upwards
Sort downwards
Identification | Q min. (L/min) |
Q max. (L/min) |
A (mm) |
B (mm) |
Screw-in housing | Screw-in thread | Setting range with Qon min. (L/min) |
Setting range with Qon max. (L/min) |
Weight (kg) |
---|---|---|---|---|---|---|---|---|---|
HK BFCV 08 NS0 02 | 8 | 22 | 41,0 | 40,0 | HK GEH 38 C 0830 | SAE 08/3 3/4"-16UNF-2B | 4,0 | 8,0 | 0,2 |
HK BFCV 08 NS0 03 | 11 | 22 | 41,0 | 40,0 | HK GEH 38 C 0830 | SAE 08/3 3/4"-16UNF-2B | 5,5 | 11,0 | 0,2 |
HK BFCV 08 NS0 05 | 19 | 22 | 41,0 | 40,0 | HK GEH 38 C 0830 | SAE 08/3 3/4"-16UNF-2B | 9,5 | 19,0 | 0,2 |
HK BFCV 10 NS0 08 | 30 | 45 | 48,3 | 47,3 | HK GEH 38 C1030 | SAE 10/3 7/8"-14UNF-2B | 15,0 | 30,0 | 0,2 |
HK BFCV 12 NS0 15 | 57 | 76 | 49,8 | 67,3 | HK GEH 12 C1230 | SAE 12/3 1.1/16"-12UNF-2B | 28,5 | 57,0 | 0,2 |
HK BFCV 12 NS0 18 | 68 | 76 | 49,8 | 67,3 | HK GEH 12 C1230 | SAE 12/3 1.1/16"-12UNF-2B | 34,0 | 68,0 | 0,2 |
Qein - intake volumetric flow – Qmax - max intake volumetric flow – Qmin - min. volumetric flow for control function
Accessories
- HK GEH 30 AL
- Aluminium housing for SAE 3-way cartridge valve
- HK GEH 30 GGG
- GGG40 housing for SAE 3-way cartridge valve
Disclaimer
Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.