HK CB L
Overcentre valve CBProduct image
Properties
Operating pressure |
max. 350 bar |
Description
load-holding function to 210bar (with setting 280 bar, opening of load pressure 0 bar)
Load-dependent opening for controlling negative (dragging) loads
back pressure on connection 2 can impair the functioning of the valve
closing pressure >= 85% of the opening pressure
Note! Relief function by screwing in the spindle
Note
These valves must be set according to the application.
Item
Sort upwards
Sort downwards
Identification | Pressure setting range min. (bar) |
Pressure setting range max. (bar) |
Qmax (L/min) |
A (mm) |
B (mm) |
Screw-in housing | Screw-in thread | AF (mm) |
Tightening torque (N-m) |
Level control ratio | Weight (kg) |
---|---|---|---|---|---|---|---|---|---|---|---|
HK CB BY LHN | 70 | 280 | 20 | 50,0 | 35,0 | HK EBAM / HK EBAT / HK EBY / HK EBYS / HK YEU | T-11A | 22 | 50,0 | 1:2 | 0,5 |
HK CB CA LIN | 25 | 105 | 60 | 50,0 | 35,0 | HK EBAM / HK EBAT / HK EBY / HK EBYS / HK YEU | T-11A | 22 | 50,0 | 1:3 | 0,5 |
HK CB CA LHN | 70 | 280 | 60 | 50,0 | 35,0 | HK EBAM / HK EBAT / HK EBY / HK EBYS / HK YEU | T-11A | 22 | 50,0 | 1:3 | 0,5 |
HK CB EA LIN | 25 | 105 | 120 | 61,0 | 35,0 | HK BCV / HK BCVS / HK BCW / HK BCWS / HK YAV | T-2A | 28 | 65,0 | 1:3 | 0,5 |
HK CB EA LHN | 70 | 280 | 120 | 61,0 | 35,0 | HK BCV / HK BCVS / HK BCW / HK BCWS / HK YAV | T-2A | 28 | 65,0 | 1:3 | 0,5 |
Accessories
- HK GEH BC
- Valve housing for cartridge valve T-2A
- HK GEH EBA
- Housing sandwich plate with measurement connctn. for cart. valve T-11A
- HK GEH EBY
- Housing sandwich plate with measurement connctn. for cart. valve T-11A
- HK GEH YA
- Valve housing for cartridge valve T-2A
- HK GEH YE
- Valve housing for cartridge valve T-11A
- HK HR SUN
- Hand wheel for cartridge valve SUN
Disclaimer
Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.