Solenoid-operated directional control valve NG10Product image
Properties
Design |
4/2-way valve or 4/3-way valve with manual emergency operation |
Scope of supply |
with coil, without plug |
Operating pressure |
P, A, B: max. 315bar / T: max. 160bar (VDC) / T: max. 120bar (VAC) |
Volumetric flow |
max. 120 l/min (note characteristic curves) |
Connection |
ISO/Cetop 05 size 10 |
Mounting |
4 pcs. socket head screw M6x40 12.9 |
protection class |
IP 65 |
Description
switching capacity limits see characteristic curves
Item
Sort upwards
Sort downwards
Identification | Circuit diagram | Type | Piston type | Rated voltage/ current type |
Overlap | Design | Weight (kg) |
---|---|---|---|---|---|---|---|
HK DG4V5 0BJ VM U 12DC | 4/2 | 0BJ [PB/AT]-[ABPT] | 12 VDC | negative (open) | Spring return | 3,60 | |
HK DG4V5 0BJ VM U 24DC | 4/2 | 0BJ [PB/AT]-[ABPT] | 24 VDC | negative (open) | Spring return | 3,60 | |
HK DG4V5 0B VM U 110AC | 4/2 | 0B [PB/AT]-[ABPT] | 110 VAC | negative (open) | Spring return | 3,60 | |
HK DG4V5 0B VM U 230AC | 4/2 | 0B [PB/AT]-[ABPT] | 230 VAC 50 Hz | negative (open) | Spring return | 3,60 | |
HK DG4V5 2AJ VM U 12DC | 4/2 | 2AJ [PB/AT]-[PA/BT] | 12 VDC | positive (closed) | Spring return | 3,60 | |
HK DG4V5 2AJ VM U 24DC | 4/2 | 2AJ [PB/AT]-[PA/BT] | 24 VDC | positive (closed) | Spring return | 3,60 | |
HK DG4V5 2A VM U 110AC | 4/2 | 2A [PB/AT]-[PA/BT] | 110 VAC | positive (closed) | Spring return | 3,60 | |
HK DG4V5 2A VM U 230AC | 4/2 | 2A [PB/AT]-[PA/BT] | 230 VAC 50 Hz | positive (closed) | Spring return | 3,60 | |
HK DG4V5 2ALJ VM U 12DC | 4/2 | 2ALJ [PB/AT]-[PA/BT] | 12 VDC | positive (closed) | Spring return | 3,60 | |
HK DG4V5 2ALJ VM U 24DC | 4/2 | 2ALJ [PB/AT]-[PA/BT] | 24 VDC | positive (closed) | Spring return | 3,60 | |
HK DG4V5 2AL VM U 110AC | 4/2 | 2AL [PB/AT]-[PA/BT] | 110 VAC | positive (closed) | Spring return | 3,60 | |
HK DG4V5 2AL VM U 230AC | 4/2 | 2AL [PB/AT]-[PA/BT] | 230 VAC 50 Hz | positive (closed) | Spring return | 3,60 | |
HK DG4V5 2BJ VM U 12DC | 4/2 | 2BJ [PB/AT]-[A/B/P/T] | 12 VDC | positive (closed) | Spring return | 3,60 | |
HK DG4V5 2BJ VM U 24DC | 4/2 | 2BJ [PB/AT]-[A/B/P/T] | 24 VDC | positive (closed) | Spring return | 3,60 | |
HK DG4V5 2B VM U 110AC | 4/2 | 2B [PB/AT]-[A/B/P/T] | 110 VAC | positive (closed) | Spring return | 3,60 | |
HK DG4V5 2B VM U 230AC | 4/2 | 2B [PB/AT]-[A/B/P/T] | 230 VAC 50 Hz | positive (closed) | Spring return | 3,60 | |
HK DG4V5 6BJ VM U 12DC | 4/2 | 6BJ [PB/AT]-[ABT/P] | 12 VDC | positive (closed) | Spring return | 3,60 | |
HK DG4V5 6BJ VM U 24DC | 4/2 | 6BJ [PB/AT]-[ABT/P] | 24 VDC | positive (closed) | Spring return | 3,60 | |
HK DG4V5 6B VM U 110AC | 4/2 | 6B [PB/AT]-[ABT/P] | 110 VAC | positive (closed) | Spring return | 3,60 | |
HK DG4V5 6B VM U 230AC | 4/2 | 6B [PB/AT]-[ABT/P] | 230 VAC 50 Hz | positive (closed) | Spring return | 3,60 | |
HK DG4V5 22AJ VM U 12DC | 4/2 | 22AJ [PB/A/T]-[PA/B/T] | 12 VDC | positive (closed) | Spring return | 3,60 | |
HK DG4V5 22AJ VM U 24DC | 4/2 | 22AJ [PB/A/T]-[PA/B/T] | 24 VDC | positive (closed) | Spring return | 3,60 | |
HK DG4V5 22A VM U 110AC | 4/2 | 22A [PB/A/T]-[PA/B/T] | 110 VAC | positive (closed) | Spring return | 3,60 | |
HK DG4V5 22A VM U 230AC | 4/2 | 22A [PB/A/T]-[PA/B/T] | 230 VAC 50 Hz | positive (closed) | Spring return | 3,60 | |
HK DG4V5 0CJ VM U 12DC | 4/3 | 0CJ [PB/AT]-[ABPT]-[PA/BT] | 12 VDC | negative (open) | spring return to 0 | 4,30 | |
HK DG4V5 0CJ VM U 24DC | 4/3 | 0CJ [PB/AT]-[ABPT]-[PA/BT] | 24 VDC | negative (open) | spring return to 0 | 4,30 | |
HK DG4V5 0C VM U 110AC | 4/3 | 0C [PB/AT]-[ABPT]-[PA/BT] | 110 VAC | negative (open) | spring return to 0 | 4,30 | |
HK DG4V5 0C VM U 230AC | 4/3 | 0C [PB/AT]-[ABPT]-[PA/BT] | 230 VAC 50 Hz | negative (open) | spring return to 0 | 4,30 | |
HK DG4V5 2CJ VM U 12DC | 4/3 | 2CJ [PB/AT]-[A/B/P/T]-[PA/BT] | 12 VDC | positive (closed) | spring return to 0 | 4,30 | |
HK DG4V5 2CJ VM U 24DC | 4/3 | 2CJ [PB/AT]-[A/B/P/T]-[PA/BT] | 24 VDC | positive (closed) | spring return to 0 | 4,30 | |
HK DG4V5 2C VM U 110AC | 4/3 | 2C [PB/AT]-[A/B/P/T]-[PA/BT] | 110 VAC | positive (closed) | spring return to 0 | 4,30 | |
HK DG4V5 2C VM U 230AC | 4/3 | 2C [PB/AT]-[A/B/P/T]-[PA/BT] | 230 VAC 50 Hz | positive (closed) | spring return to 0 | 4,30 | |
HK DG4V5 6CJ VM U 12DC | 4/3 | 6CJ [PB/AT]-[ABT/P]-[PA/BT] | 12 VDC | positive (closed) | spring return to 0 | 4,30 | |
HK DG4V5 6CJ VM U 24DC | 4/3 | 6CJ [PB/AT]-[ABT/P]-[PA/BT] | 24 VDC | positive (closed) | spring return to 0 | 4,30 | |
HK DG4V5 6C VM U 110AC | 4/3 | 6C [PB/AT]-[ABT/P]-[PA/BT] | 110 VAC | positive (closed) | spring return to 0 | 4,30 | |
HK DG4V5 6C VM U 230AC | 4/3 | 6C [PB/AT]-[ABT/P]-[PA/BT] | 230 VAC 50 Hz | positive (closed) | spring return to 0 | 4,30 | |
HK DG4V5 8CJ VM U 12DC | 4/3 | 8CJ [PA/BT]-[A/B/PT]-[PB/AT] | 12 VDC | negative (open) | spring return to 0 | 4,30 | |
HK DG4V5 8CJ VM U 24DC | 4/3 | 8CJ [PA/BT]-[A/B/PT]-[PB/AT] | 24 VDC | negative (open) | spring return to 0 | 4,30 | |
HK DG4V5 8CJ VM U 110AC | 4/3 | 8CJ [PA/BT]-[A/B/PT]-[PB/AT] | 110 VAC | negative (open) | spring return to 0 | 4,30 | |
HK DG4V5 8CJ VM U 230AC | 4/3 | 8CJ [PA/BT]-[A/B/PT]-[PB/AT] | 230 VAC 50 Hz | negative (open) | spring return to 0 | 4,30 | |
HK DG4V5 2NJ VM U 12DC | 4/3 | 2NJ [PB/AT]-[PA/BT] | 12 VDC | positive (closed) | 2 latching positions | 4,30 | |
HK DG4V5 2NJ VM U 24DC | 4/3 | 2NJ [PB/AT]-[PA/BT] | 24 VDC | positive (closed) | 2 latching positions | 4,30 | |
HK DG4V5 2N VM U 110AC | 4/3 | 2N [PB/AT]-[PA/BT] | 110 VAC | positive (closed) | 2 latching positions | 4,30 | |
HK DG4V5 2N VM U 230AC | 4/3 | 2N [PB/AT]-[PA/BT] | 230 VAC 50 Hz | positive (closed) | 2 latching positions | 4,30 |
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]
Ordering information
Further circuits and versions, volumetric flows and switching power limits on request
Accessories
- HK SP DG4V5
- Coil for HK DG4V5 solenoid-operated valve
- HK SP DIN 43650
- Electrical plug for solenoid coil DIN 43650 / ISO 4400
- HK M HK DK
- Set of bolts for NG 10 valves types HK DK11/DKE/DG4V5
Disclaimer
Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.