HK EMDV
2/2-way solenoid-controlled seat valve EMDVProduct image
Properties
Scope of supply |
with coil, without plug |
Operating pressure |
max. 350 bar |
Note
Caution!
Type HKEMDV10N01/NC1 valves are not seat valves
Please use rectifier plug HKSP669 for HKEMDV08***230AC valves
Tightening torque for valve size 08 with Alu housing: 34-41 Nm
Tightening torque for valve size 08 with Steel housing: 47-54 Nm
Tightening torque for valve size 10 with Alu housing: 47-54 Nm
Tightening torque for valve size 10 with Steel housing: 74-81 Nm
Tightening torque for valve size 12 with Alu housing: 74-81 Nm
Tightening torque for valve size 12 with Steel housing: 95-102 Nm
Item
Sort upwards
Sort downwards
Identification | Circuit diagram | Control | Volumetric flow max. (L/min) |
A (mm) |
B (mm) |
C (mm) |
Screw-in housing | Screw-in thread | Design | Rated voltage/ current type |
Weight (kg) |
---|---|---|---|---|---|---|---|---|---|---|---|
HK EMDV 08 N08 12DC | pilot-controlled | 38,0 | 78,7 | 27,9 | 34,3 | HK GEH 38 C 0820 | SAE 8/2 3/4"-16UNF-2B | (1) | 12 VDC | 0,36 | |
HK EMDV 08 N08 24DC | pilot-controlled | 38,0 | 78,7 | 27,9 | 34,3 | HK GEH 38 C 0820 | SAE 8/2 3/4"-16UNF-2B | (1) | 24 VDC | 0,36 | |
HK EMDV 08 N08 230AC | pilot-controlled | 38,0 | 78,7 | 27,9 | 34,3 | HK GEH 38 C 0820 | SAE 8/2 3/4"-16UNF-2B | (1) | 230 VAC | 0,36 | |
HK EMDV 08 NC8 12DC | pilot-controlled | 38,0 | 71,1 | 27,9 | 34,3 | HK GEH 38 C 0820 | SAE 8/2 3/4"-16UNF-2B | (1) | 12 VDC | 0,36 | |
HK EMDV 08 NC8 24DC | pilot-controlled | 38,0 | 71,1 | 27,9 | 34,3 | HK GEH 38 C 0820 | SAE 8/2 3/4"-16UNF-2B | (1) | 24 VDC | 0,36 | |
HK EMDV 08 NC8 230AC | pilot-controlled | 38,0 | 71,1 | 27,9 | 34,3 | HK GEH 38 C 0820 | SAE 8/2 3/4"-16UNF-2B | (1) | 230 VAC | 0,36 | |
HK EMDV 08 NC3 12DC | directly controlled | 19,0 | 78,7 | 27,9 | 34,3 | HK GEH 38 C 0820 | SAE 8/2 3/4"-16UNF-2B | (1) | 12 VDC | 0,41 | |
HK EMDV 08 NC3 24DC | directly controlled | 19,0 | 78,7 | 27,9 | 34,3 | HK GEH 38 C 0820 | SAE 8/2 3/4"-16UNF-2B | (1) | 24 VDC | 0,41 | |
HK EMDV 08 NC3 230AC | directly controlled | 19,0 | 78,7 | 27,9 | 34,3 | HK GEH 38 C 0820 | SAE 8/2 3/4"-16UNF-2B | (1) | 230 VAC | 0,41 | |
HK EMDV 10 N01 12DC | directly controlled | 30,0 | 93,2 | 32,5 | 45,2 | HK GEH 38 C1020 | SAE 10/2 7/8"-14UNF-2B | (2) | 12 VDC | 0,88 | |
HK EMDV 10 N01 24DC | directly controlled | 30,0 | 93,2 | 32,5 | 45,2 | HK GEH 38 C1020 | SAE 10/2 7/8"-14UNF-2B | (2) | 24 VDC | 0,88 | |
HK EMDV 10 N01 230AC | directly controlled | 30,0 | 93,2 | 32,5 | 45,2 | HK GEH 38 C1020 | SAE 10/2 7/8"-14UNF-2B | (2) | 230 VAC | 0,88 | |
HK EMDV 10 NC1 12DC | directly controlled | 30,0 | 93,2 | 32,5 | 45,2 | HK GEH 38 C1020 | SAE 10/2 7/8"-14UNF-2B | (2) | 12 VDC | 0,88 | |
HK EMDV 10 NC1 24DC | directly controlled | 30,0 | 93,2 | 32,5 | 45,2 | HK GEH 38 C1020 | SAE 10/2 7/8"-14UNF-2B | (2) | 24 VDC | 0,88 | |
HK EMDV 10 NC1 230AC | directly controlled | 30,0 | 93,2 | 32,5 | 45,2 | HK GEH 38 C1020 | SAE 10/2 7/8"-14UNF-2B | (2) | 230 VAC | 0,88 | |
HK EMDV 12 N04 12DC | pilot-controlled | 136,0 | 90,5 | 44,4 | 45,2 | HK GEH 12 C1220 / HK GEH 34 C1220 | SAE 12/2 1.1/16"-12UNF-2B | (2) | 12 VDC | 0,90 | |
HK EMDV 12 N04 24DC | pilot-controlled | 136,0 | 90,5 | 44,4 | 45,2 | HK GEH 12 C1220 / HK GEH 34 C1220 | SAE 12/2 1.1/16"-12UNF-2B | (2) | 24 VDC | 0,90 | |
HK EMDV 12 N04 230AC | pilot-controlled | 136,0 | 90,5 | 44,4 | 45,2 | HK GEH 12 C1220 / HK GEH 34 C1220 | SAE 12/2 1.1/16"-12UNF-2B | (2) | 230 VAC | 0,90 | |
HK EMDV 12 NC4 12DC | pilot-controlled | 136,0 | 90,5 | 44,4 | 45,2 | HK GEH 12 C1220 / HK GEH 34 C1220 | SAE 12/2 1.1/16"-12UNF-2B | (1) | 12 VDC | 0,90 | |
HK EMDV 12 NC4 24DC | pilot-controlled | 136,0 | 90,5 | 44,4 | 45,2 | HK GEH 12 C1220 / HK GEH 34 C1220 | SAE 12/2 1.1/16"-12UNF-2B | (1) | 24 VDC | 0,90 | |
HK EMDV 12 NC4 230AC | pilot-controlled | 136,0 | 90,5 | 44,4 | 45,2 | HK GEH 12 C1220 / HK GEH 34 C1220 | SAE 12/2 1.1/16"-12UNF-2B | (1) | 230 VAC | 0,90 |
(1) without manual emergency operation – (2) with manual emergency operation
Accessories
- HK GEH 20 AL
- Aluminium housing for SAE 2-way cartridge valve
- HK GEH 20 GGG
- GGG40 housing for SAE 2-way cartridge valve
- HK SP DIN 43650
- Electrical plug for solenoid coil DIN 43650 / ISO 4400
- HK SP EMDV
- Coil for cartridge valve EMDV
Disclaimer
Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.