HK MPS 1
Spin-on filter type 1Product image
Properties
Design |
as return filter with bypass valve 1.75 bar, without clogging indicator A10: with inorganic filter (10 μm), absolute filtration P10: paper filter (10 μm), nominal filtration |
Temp. min. |
-25 °C |
Temp. max. |
110 °C |
Material |
Filter head in aluminum Gasket: NBR |
Operating pressure |
max. 12 bar |
Description
Spin-on filters for pipeline installation
Pressure differential for paper filter element (P) max. 4 bar
Pressure differential for filter inorganic element (A) max. 4 bar
Design (Qmax.) for medium ISO VG 46
at 50°C (30 mm2/s) at Δptot = 0.4 bar
Note
For utilization as a suction filter a suction filter head FI SP S FK *** must be used.
Item
Sort upwards
Sort downwards
Identification | Filter mesh size (μm) |
Filter area | Line connection | Q max. (L/min) |
A (mm) |
B (mm) |
C (mm) |
D (mm) |
E (mm) |
Weight (kg) |
---|---|---|---|---|---|---|---|---|---|---|
HK MPS 050 RG1 A10 | 10,0 | 1900 | G 3/4” | 48 | 180 | 22 | 200 | 95 | 96 | 1,0 |
HK MPS 050 RG1 P10 | 10,0 | 2240 | G 3/4” | 56 | 180 | 22 | 200 | 95 | 96 | 1,0 |
HK MPS 070 RG1 A10 | 10,0 | 3160 | G 3/4” | 53 | 248 | 22 | 268 | 95 | 96 | 1,3 |
HK MPS 070 RG1 P10 | 10,0 | 4140 | G 3/4” | 65 | 248 | 22 | 268 | 95 | 96 | 1,3 |
HK MPS 100 RG1 A10 | 10,0 | 3950 | G 1.1/4” | 110 | 241 | 30 | 286 | 133 | 129 | 2,2 |
HK MPS 100 RG1 P10 | 10,0 | 4300 | G 1.1/4” | 149 | 241 | 30 | 286 | 133 | 129 | 2,2 |
HK MPS 150 RG1 A10 | 10,0 | 5390 | G 1.1/4” | 115 | 286 | 30 | 311 | 133 | 129 | 2,3 |
HK MPS 150 RG1 P10 | 10,0 | 5760 | G 1.1/4” | 156 | 286 | 30 | 311 | 133 | 129 | 2,3 |
A10 with inorganic filter (10 μm), absolute filtration – P10 paper filter (10 μm), nominal filtration – Qmax - max intake volumetric flow
Ordering information
Other filter materials and filters for other types of oil, viscosities or temperatures available on request
Accessories
- HK VA MAN
- Clogging indicator pressure gauge
Spare parts
- HK MPS R/S
- Filter head for spin-on filter MPS
Disclaimer
Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.