K-DIGIT PRAEZ DRUCKSCHA ISE
Digital pressure switch ISEProduct image
Properties
Design |
Precision Digital Pressure Switch for excess pressure |
Design |
with switching function display unit |
max. output pressure |
1,05 MPa |
min. output pressure |
-105,00 kPa |
max. nominal pressure |
1,0 MPa |
min. nominal pressure |
-100,0 kPa |
Reacting time |
max. 2,5 ms |
Rated voltage |
12 to 24 VDC |
Test pressure |
1,50 MPa |
Protection IP |
IP 65 |
Current consumption |
80 mA |
Approval |
CE, UL/CSA, RoHS |
Media temperature |
-5 °C to +50 °C |
Ambient temperature |
-5 °C bis +50 °C |
Media |
Compressed air, non-corrosive gases, non-flammable gases |
Series |
ISE40A |
More information |
Compact, design user-friendly operation Copy function to copy settings on up to 10 sub-sensors Energy saving function automatically switches off the display after 30 seconds Anti-chattering function, selectable units, Adjustable hysteresis Extended connection cable to 3.00 m Pre-wired M12 connector with 4 pins (Lead wire length 100 mm) |
Description
Digital precision pressure switch for overpressure, series ISE40A, 3 1/2-digit, 7-segment display, 2-colour (red/green), compact design, user-friendly operation, copy function, settings can be copied to up to 10 subordinate sensors, energy saving function,
the display switches off automatically after 30 seconds, anti-chattering function, free choice of units, adjustable hysteresis, 2 m connection cable with plug included
Item
Sort upwards
Sort downwards
Identification | Repeatability | Pneumatic Port | Electrical outlet |
---|---|---|---|
K- 07 50 00 06 | ±2 % | R 1/8 (M 5-internal thread) | PNP open collector, 2 Outputs + analog Voltage/Auto-Reference Input |
K- 07 50 00 07 | ±2 % | R 1/8 (M 5-internal thread) | PNP open collector, 2 Outputs + analog Voltage/Auto-Reference Input |
K- 07 50 00 08 | ±2 % | R 1/8 (M 5-internal thread) | PNP open collector, 2 Outputs + analog Ampere/Auto-Reference Input |
K- 07 50 00 09 | ±2 % | R 1/8 (M 5-internal thread) | PNP open collector, 2 Outputs + analog Ampere/Auto-Reference Input |
K- 07 50 00 10 | ±2 % | R 1/8 (M 5-internal thread) | NPN open collector, 2 Outputs + Copyfunction |
K- 07 50 00 11 | ±2 % | R 1/8 (M 5-internal thread) | PNP open collector, 2 Outputs + Copyfunction |
K- 07 50 00 12 | ±2 % | R 1/8 (M 5-internal thread) | PNP open collector, 2 Outputs + Copyfunction |
K- 07 50 00 13 | ±2 % | R 1/8 (M 5-internal thread) | PNP open collector, 2 Outputs + Copyfunction |
K- 07 50 00 14 | ±2 % | R 1/8 (M 5-internal thread) | PNP open collector, 2 Outputs + Copyfunction |
K- 07 50 00 15 | ±2 % | for hose outer-Ø 4 mm | PNP open collector, 2 Outputs + analog Voltage/Auto-Reference Input |
K- 07 50 00 16 | ±2 % | for hose outer-Ø 4 mm | PNP open collector, 2 Outputs + analog Ampere/Auto-Reference Input |
K- 07 50 00 17 | ±2 % | for hose outer-Ø 4 mm | PNP open collector, 2 Outputs + Copyfunction |
K- 07 50 00 18 | ±2 % | for hose outer-Ø 6 mm | PNP open collector, 2 Outputs + analog Voltage/Auto-Reference Input |
K- 07 50 00 19 | ±2 % | for hose outer-Ø 6 mm | PNP open collector, 2 Outputs + analog Ampere/Auto-Reference Input |
K- 07 50 00 20 | ±2 % | for hose outer-Ø 6 mm | PNP open collector, 2 Outputs + Copyfunction |
K- 07 50 00 21 | ±2 % | M 5 x 0,8 (internal thread) | PNP open collector, 2 Outputs + analog Voltage/Auto-Reference Input |
K- 07 50 00 22 | ±2 % | Rc 1/8 | PNP open collector, 2 Outputs + analog Voltage/Auto-Reference Input |
K- 07 50 00 23 | ±2 % | Rc 1/8 | PNP open collector, 2 Outputs + analog Voltage/Auto-Reference Input |
K- 07 50 00 24 | ±2 % | Rc 1/8 | PNP open collector, 2 Outputs + analog Ampere/Auto-Reference Input |
K- 07 50 00 25 | ±2 % | Rc 1/8 | PNP open collector, 2 Outputs + analog Ampere/Auto-Reference Input |
K- 07 50 00 26 | ±2 % | G 1/8 | PNP open collector, 2 Outputs + analog Voltage/Auto-Reference Input |
K- 07 50 00 27 | ±2 % | G 1/8 | PNP open collector, 2 Outputs + analog Ampere/Auto-Reference Input |
Disclaimer
Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.