HK EPRM CD
EPRM geroller motorProduct image
Properties
Connection |
Oil fittings: A + B = G 1/2"; leak oil = G 1/4" |
Design |
Standard variant Type "CD" with high-pressure gasket two hole flange bolt circle 106.4 Shaft Ø 25mm |
Intake and return pressure with leak oil line max. |
175 bar |
Item
Sort upwards
Sort downwards
Identification | Flow rate max. (L/min) |
Displacement (cc) |
Speed min. (rpm) |
Speed max. (rpm) |
Torque max. (N-m) |
Pressure drop max. (bar) |
Pmax. at 0-100 rpm (bar) |
Pmax. at 100-300 rpm (bar) |
Pmax. at 300-600 rpm (bar) |
Pmax. at >600 rpm (bar) |
L (mm) |
Weight (kg) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
HK EPRM 050 CD | 40 | 51,5 | 10 | 775 | 100 | 140 | 150 | 75 | 50 | 20 | 138 | 6,8 |
HK EPRM 080 CD | 60 | 80,3 | 10 | 750 | 195 | 175 | 150 | 75 | 50 | 20 | 143 | 6,9 |
HK EPRM 100 CD | 60 | 99,8 | 10 | 600 | 240 | 175 | 150 | 75 | 50 | - | 147 | 7,2 |
HK EPRM 125 CD | 60 | 125,7 | 10 | 475 | 300 | 175 | 150 | 75 | 50 | - | 151 | 7,3 |
HK EPRM 160 CD | 60 | 159,6 | 10 | 375 | 390 | 175 | 150 | 75 | 50 | - | 157 | 7,5 |
HK EPRM 200 CD | 60 | 199,8 | 10 | 300 | 385 | 140 | 150 | 75 | - | - | 164 | 8,0 |
HK EPRM 250 CD | 60 | 250,1 | 10 | 240 | 390 | 110 | 150 | 75 | - | - | 173 | 8,4 |
HK EPRM 315 CD | 60 | 315,7 | 10 | 190 | 390 | 90 | 150 | 75 | - | - | 184 | 9,1 |
HK EPRM 400 CD | 60 | 397,0 | 10 | 150 | 380 | 70 | 150 | 75 | - | - | 198 | 9,8 |
max. pressure on shaft seal (without leak oil line) or pressure in leak oil line – Values for torque and pressure drop apply for continuous operation – pmax = max. pressure
Accessories
- HK V0 590
- Shock valve
Spare parts
- HK EP DS
- Seal kit for hydraulic planetary motor
Disclaimer
Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.