FI RL E MP
Filter element for return filter MPProduct image
Properties
Temp. min. |
-25 °C |
Temp. max. |
120 °C |
Material |
Gasket: NBR |
Use |
For return flow filter FI RL |
Description
Pressure differential for filter element paper (P) max. 3 bar
Pressure differential for inorganic filter element (A) max. 10 bar
Item
Sort upwards
Sort downwards
Identification | Filter mesh size (μm) |
Filter area (cm2) |
Qmax (L/min) |
Filter material | for filter type | Ø A (mm) |
Ø B (mm) |
L (mm) |
bypass valve | Weight (kg) |
---|---|---|---|---|---|---|---|---|---|---|
FI RL E MP 0072 A10 | 10,0 | 313 | 25 | inorganic | FI RL 024, 048 | 52 | 24,5 | 72,00 | with | 0,16 |
FI RL E MP 0072 P10 | 10,0 | 392 | 25 | organic | FI RL 024, 048 | 52 | 24,5 | 72,00 | with | 0,16 |
FI RL E MP 0085 A10 | 10,0 | 690 | 100 | inorganic | FI RL 053, 086 | 70 | 29,5 | 85,00 | with | 0,20 |
FI RL E MP 0085 P10 | 10,0 | 828 | 100 | organic | FI RL 053, 086 | 70 | 29,5 | 85,00 | with | 0,16 |
FI RL E MP 0130 A10 | 10,0 | 1140 | 100 | inorganic | FI RL 064, 150 | 70 | 29,5 | 130,00 | with | 0,22 |
FI RL E MP 0130 P10 | 10,0 | 1368 | 100 | organic | FI RL 064, 150 | 70 | 29,5 | 130,00 | with | 0,22 |
FI RL E MP 0145 A10 | 10,0 | 3600 | 600 | inorganic | FI RL 290, 370 | 130 | 51,5 | 145,00 | with | 1,00 |
FI RL E MP 0145 P10 | 10,0 | 4000 | 600 | organic | FI RL 290, 370 | 130 | 51,5 | 145,00 | with | 1,00 |
FI RL E MP 0204 A10 | 10,0 | 5299 | 300 | inorganic | FI RL 320, 450 | 130 | 64,5 | 204,00 | with | 1,00 |
FI RL E MP 0204 P10 | 10,0 | 5888 | 300 | organic | FI RL 320, 450 | 130 | 64,5 | 204,00 | with | 1,00 |
FI RL E MP 0211 A10 | 10,0 | 1358 | 150 | inorganic | FI RL 125, 225 | 70 | 40,5 | 211,50 | with | 0,28 |
FI RL E MP 0211 P10 | 10,0 | 1629 | 150 | organic | FI RL 125, 225 | 70 | 40,5 | 211,50 | with | 0,28 |
FI RL E MP 0220 A10 | 10,0 | 3360 | 250 | inorganic | FI RL 190, 230 | 99 | 40,5 | 220,00 | with | 0,70 |
FI RL E MP 0220 P10 | 10,0 | 3840 | 250 | organic | FI RL 190, 230 | 99 | 40,5 | 220,00 | with | 0,70 |
FI RL E MP 0254 A10 | 10,0 | 6739 | 380 | inorganic | FI RL 420, 540, 675 | 130 | 64,5 | 254,00 | with | 1,19 |
FI RL E MP 0254 P10 | 10,0 | 7488 | 380 | organic | FI RL 420, 540, 675 | 130 | 64,5 | 254,00 | with | 1,19 |
FI RL E MP 0404 A10 | 10,0 | 11059 | 600 | inorganic | FI RL 620, 750 | 130 | 64,5 | 404,00 | with | 2,00 |
FI RL E MP 0404 P10 | 10,0 | 12288 | 600 | organic | FI RL 620, 750 | 130 | 64,5 | 404,00 | with | 2,00 |
FI RL E MP 0050 A25 | 25,0 | 1140 | 100 | inorganic | FI RL 064, 150 | 70 | 29,5 | 130,00 | with | 0,28 |
FI RL E MP 0050 P25 | 25,0 | 1368 | 100 | organic | FI RL 064, 150 | 70 | 29,5 | 130,00 | with | 0,16 |
FI RL E MP 0120 A25 | 25,0 | 3259 | 300 | inorganic | - | 99 | 51,5 | 210,00 | without | 0,53 |
FI RL E MP 0200 A25 | 25,0 | 11325 | 600 | inorganic | - | 130 | 76,0 | 500,00 | without | 0,50 |
Qmax - max intake volumetric flow
Spare part for following products
- FI RL
- Return flow filters
Additional elements
- FI RL GEH
- Housing for return flow filter
Disclaimer
Despite careful checking, we cannot guarantee the accuracy of all information included on this site, and we accept no liability.
All data and information in our online catalogue are based on currently valid standards and the regulations from the employer's liability insurance association. Product safety can only be guaranteed when our assembly instructions are carefully observed. Non-adherence to these regulations can affect product operation and functioning and result in a loss of warranty. Our warranty is only valid for HANSA-FLEX products. Our products are constantly subject to further development and technical changes are therefore possible.